Maintenance
4-4
Section 4
WATER PUMP
POWER CORD
OUTLET
B. Remove the Overflow Tube
To remove the tube, lift it up while using a slight
back and forth motion to loosen it from the drain
hole.
When installing the tube, be sure it is completely
inserted into the drain hole to prevent water leakage
during normal operation.
Removing the Overflow Tube
C. Remove the Vinyl Hose
Disconnect the water pump discharge hose from
the distribution tube and water pump.
D. Remove the Water Pump
Disconnect the water pump power cord.
Disconnect the water hose from the pump outlet.
Loosen the screws that hold the water pump in
place.
Lift the water pump and bracket assembly up and
off the screws.
Removing the Water Pump
E. Remove the Water Trough
Remove the screws holding the water trough to
the walls of the cabinet.